130 foto's
Locatie
Newnan, GA
Newnan, GA
Gebruik
7.071 uren
7.071 uren
Serienummer
J7K53858
J7K53858
Loading...
Dit valt niet onder IronClad Assurance-dekking
Koop vol vertrouwen, want dit item is volledig en nauwkeurig geïnspecteerd door een gekwalificeerde inspecteur.
ID-nummer
#12719169
Op veilingterrein
Ja
Kenmerken
Air Conditioner, Anti Two-Block, 7071 hrs Crane Operation, Cummins QSL9 6 Cylinder 333 hp 8.9 L Diesel Engine, 40 ft Minimum 150 ft Maximum Boom Length, Auxiliary Hoist, Rooster Sheave, 31 ft to 55 ft Bifold Offset Jib, 1349 lb 80 ton Capacity Johnson 5 Sheave Hook Block, 698 lb 12 ton Capacity Overhaul Ball, 24000 ton Counterweight























Serial Number / VIN
J7K53858
CE Mark
No CE mark found
Hour Meter / Odometer
7071 hrs-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
Glass
Exterior Lights
Operational, Busted tail lights
Safety Certification Label
There was no safety certification label located on the machine.
Safety Certification Report
Safety Certification Report Not Available
Load Chart
Yes, Book

Travel Alarm
Operational
Horn
Inoperable
Seat Belts
Operational
Safety Lock Out/Stop
Operational
Current Safety Manual
Current Operator/Maintenance Manual


Hours of Crane Operation
7071 hrs Crane Operation
























Mirrors
Glass
No visible damage
Seats/Armrests
Operator seat is not bolted down
Load Moment Indicator
Operational, Powers On
Anti Two Block
Not operationally checked, Disassembled parts
Hydraulic Controls
Missing switches
Drivetrain Controls
Oil Pressure
Missing decals that go over the warning lights, cannot verify
Warning Lights
Inoperable
Gauges
Operational
Air Conditioner
Inoperable, Missing switches
Heater
Inoperable, Missing switches
Limited Function Check
The main components are in place and operational as noted.








Emission Label
A/C Compressor
Cannot verify ac system missing switches
Blow-by (subjective visual observation)
Visible
Starter
Operational
Exhaust System
Radiator
Need tools to access radiator cap
Oil Leaks
No dripping leaks
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
Limited Function Check
The engine started and ran. Some battery post nuts are missing







Transmission
Operational
Final Drives
Limited Function Check
The drivetrain was operational.




















Pumps (Hydraulics)
Hydraulic Motors
Dripping leak
Valves
Dripping leak
Hydraulic Tank
Hoses (Hydraulic)
Swing Motor
No access
Main Hoist
Auxiliary Hoist
Lift Cylinders
Dripping leak
Telescopic Boom Cylinders
No access
Cylinder Pins and Bushings
Limited Function Check
The hydraulic system was operational. All suspension cylinders have seepage




































Steering Linkage
Steering Wheel Play
Brake Type
Air over hydraulic
Master Cylinder/Brake Control
Brake Lines/Hoses
Park Brake
Limited Function Check - Brakes
The brake system functioned, stopping and holding the machine.
Turntable Bearing
Frame Condition
Tire Size
All of the tires are the same size, 23.5R25 Front tires, LF Goodyear, LR Goodyear, RR Goodyear, RF Goodyear
Left Front Tire
Left Rear Tire
Right Rear Tire
Right Front Tire
Wheel Condition
Wheel Studs
Limited Function Check
The main chassis components were operational in a limited check.
Outrigger Cylinders
Outrigger Condition
Outrigger Beams
Outrigger Floats/Pads Condition
Rear right has damaged handle
Main Boom Pins
Main Boom Sections
Sheaves
Boom Head Section
Wear Pads
Boom Angle Indicator
Limited Function Check
The main crane components functioned when checked without a load., All suspension cylinders dripping have seepage









Jib
Main Load Block
Overhaul Ball
Counterweights
Oil Sample Analysis
| engine | |
|---|---|
| date of analysis | Apr 04, 2025 |
| Silicon | 1.76 PPM |
| Tin | 0.04 PPM |
| Silver | 0.15 PPM |
| Aluminum | 1.6 PPM |
| Chromium | 0.12 PPM |
| Lead | 0.59 PPM |
| Copper | 2.25 PPM |
| Nickel | 0.15 PPM |
| Iron | 5.48 PPM |
| Glycol | NEG |
| Water | NEG |
| Fuel | <5% |
Items moeten volledig worden betaald op uiterlijk woensdag 8 januari 3000. Extra kosten worden in rekening gebracht na de vervaldatum.
Laat uw materieel naar de gewenste locatie brengen met all-inclusive service met deur-tot-deur transportdiensten en transportoplossingen van Ritchie Bros. Wij zorgen overal voor, zodat uw materieel snel en doeltreffend over de grenzen, continenten en oceanen vervoerd wordt.
De gedetailleerde informatie over het materieel is beperkt, en Ritchie Bros. Auctioneers heeft geen andere aspecten of onderdelen van het materieel geïnspecteerd dan uitdrukkelijk in dit document vermeld. Tenzij uitdrukkelijk vermeld, geven wij geen verklaringen of garanties, expliciet of impliciet, met betrekking tot het materieel of de onderdelen ervan, met inbegrip van, maar niet beperkt tot, verklaringen of garanties met betrekking tot functionaliteit, conformiteit of naleving van veiligheidsnormen of -vereisten van een toepasselijke autoriteit of regelgevende instantie, geschiktheid voor een bepaald doel of verkoopbaarheid. U wordt ten zeerste aangeraden uw eigen gedetailleerde inspectie van het materieel uit te voeren voordat u een bod plaatst.
Materieel wordt niet getest onder belasting of gebruikt in alle beschikbare versnellingen. Wij geven geen verklaring of garantie dat het materieel volgens de specificaties van de fabrikant werkt. Er is geen inspectie uitgevoerd aan enig ander functionaliteitsaspect dan uitdrukkelijk in dit document vermeld. Er zijn alleen selecte foto's beschikbaar voor afzonderlijke onderdelen van het onderstel, en deze zijn mogelijk niet representatief voor de staat van het gehele onderstel.
Maten worden slechts bij benadering gegeven. De werkelijke afmetingen onder belasting kunnen variëren afhankelijk van de hoogte van de vrachtwagen/aanhanger en de configuratie/positie van de geladen machine. Het is de verantwoordelijkheid van de koper om alle ladingen te meten voordat deze onze veilinglocatie verlaten, om te garanderen dat de lading veilig is voor transport. Alle maten moeten door de koper worden gecontroleerd. Vertrouw niet op deze maten voor transportdoeleinden.